chamber_id_fkey |
chamber.id |
installation.id |
Restrict delete |
cover_fk_installation |
cover.fk_installation |
installation.id |
Restrict delete |
cover_fk_type |
cover.fk_cover_type |
cover_type.id |
Restrict delete |
cover_label_1_visible |
cover.label_1_visible |
visible.vl_code_int |
Restrict delete |
cover_label_2_visible |
cover.label_2_visible |
visible.vl_code_int |
Restrict delete |
crossing_pipe1 |
crossing._pipe1_id |
pipe.id |
Restrict delete |
crossing_pipe2 |
crossing._pipe2_id |
pipe.id |
Restrict delete |
district_label_1_visible |
district.label_1_visible |
visible.vl_code_int |
Restrict delete |
district_label_2_visible |
district.label_2_visible |
visible.vl_code_int |
Restrict delete |
element_fk_distributor |
network_element.fk_distributor |
distributor.id |
Restrict delete |
element_fk_folder |
network_element.fk_folder |
folder.id |
Restrict delete |
element_fk_object_reference |
network_element.fk_object_reference |
object_reference.id |
Restrict delete |
element_fk_precision |
network_element.fk_precision |
precision.id |
Restrict delete |
element_fk_precisionalti |
network_element.fk_precisionalti |
precisionalti.id |
Restrict delete |
element_fk_status |
network_element.fk_status |
status.id |
Restrict delete |
hydrant_fk_material |
hydrant.fk_material |
hydrant_material.id |
Restrict delete |
hydrant_fk_model_inf |
hydrant.fk_model_inf |
hydrant_model_inf.id |
Restrict delete |
hydrant_fk_model_sup |
hydrant.fk_model_sup |
hydrant_model_sup.id |
Restrict delete |
hydrant_fk_output |
hydrant.fk_output |
hydrant_output.id |
Restrict delete |
hydrant_fk_provider |
hydrant.fk_provider |
hydrant_provider.id |
Restrict delete |
hydrant_id_fkey |
hydrant.id |
network_element.id |
Restrict delete |
installation_fk_parent |
installation.fk_parent |
installation.id |
Restrict delete |
installation_fk_remote |
installation.fk_remote |
remote_type.id |
Restrict delete |
installation_fk_watertype |
installation.fk_watertype |
watertype.id |
Restrict delete |
installation_id_fkey |
installation.id |
network_element.id |
Restrict delete |
leak_fk_cause |
leak.fk_cause |
leak_cause.id |
Restrict delete |
leak_fk_pipe |
leak.fk_pipe |
pipe.id |
Restrict delete |
leak_label_1_visible |
leak.label_1_visible |
visible.vl_code_int |
Restrict delete |
leak_label_2_visible |
leak.label_2_visible |
visible.vl_code_int |
Restrict delete |
meter_fk_pipe |
meter.fk_pipe |
pipe.id |
Restrict delete |
meter_id_fkey |
meter.id |
network_element.id |
Restrict delete |
meter_reference_fk_meter |
meter_reference.fk_meter |
meter.id |
Restrict delete |
network_element_id_fkey |
network_element.id |
node.id |
Restrict delete |
network_element_label_1_visible |
network_element.label_1_visible |
visible.vl_code_int |
Restrict delete |
network_element_label_2_visible |
network_element.label_2_visible |
visible.vl_code_int |
Restrict delete |
network_element_schema_force_visible |
network_element.schema_force_visible |
visible.vl_code |
Restrict delete |
node_fk_district |
node.fk_district |
district.id |
Restrict delete |
node_fk_pressurezone |
node.fk_pressurezone |
pressurezone.id |
Restrict delete |
part_fk_pipe |
part.fk_pipe |
pipe.id |
Restrict delete |
part_fk_type |
part.fk_part_type |
part_type.id |
Restrict delete |
part_id_fkey |
part.id |
part.id |
Restrict delete |
pipe_fk_bedding |
pipe.fk_bedding |
bedding.id |
Restrict delete |
pipe_fk_distributor |
pipe.fk_distributor |
distributor.id |
Restrict delete |
pipe_fk_district |
pipe.fk_district |
district.id |
Restrict delete |
pipe_fk_folder |
pipe.fk_folder |
folder.id |
Restrict delete |
pipe_fk_function |
pipe.fk_function |
pipe_function.id |
Restrict delete |
pipe_fk_installmethod |
pipe.fk_installmethod |
pipe_installmethod.id |
Restrict delete |
pipe_fk_material |
pipe.fk_material |
pipe_material.id |
Restrict delete |
pipe_fk_node_a |
pipe.fk_node_a |
node.id |
Restrict delete |
pipe_fk_node_b |
pipe.fk_node_b |
node.id |
Restrict delete |
pipe_fk_parent |
pipe.fk_parent |
pipe.id |
Restrict delete |
pipe_fk_precision |
pipe.fk_precision |
precision.id |
Restrict delete |
pipe_fk_pressurezone |
pipe.fk_pressurezone |
pressurezone.id |
Restrict delete |
pipe_fk_protection |
pipe.fk_protection |
pipe_protection.id |
Restrict delete |
pipe_fk_status |
pipe.fk_status |
status.id |
Restrict delete |
pipe_fk_watertype |
pipe.fk_watertype |
watertype.id |
Restrict delete |
pipe_label_1_visible |
pipe.label_1_visible |
visible.vl_code_int |
Restrict delete |
pipe_label_2_visible |
pipe.label_2_visible |
visible.vl_code_int |
Restrict delete |
pipe_schema_force_visible |
pipe.schema_force_visible |
visible.vl_code |
Restrict delete |
pressurecontrol_fk_type |
pressurecontrol.fk_pressurecontrol_type |
pressurecontrol_type.id |
Restrict delete |
pressurecontrol_id_fkey |
pressurecontrol.id |
installation.id |
Restrict delete |
pressurezone_fk_consumptionzone |
pressurezone.fk_consumptionzone |
consumptionzone.id |
Restrict delete |
pressurezone_fk_distributor |
pressurezone.fk_distributor |
distributor.id |
Restrict delete |
pressurezone_label_1_visible |
pressurezone.label_1_visible |
visible.vl_code_int |
Restrict delete |
pressurezone_label_2_visible |
pressurezone.label_2_visible |
visible.vl_code_int |
Restrict delete |
printmap_fk_district |
printmap.fk_district |
district.id |
Restrict delete |
printmap_label_1_visible |
printmap.label_1_visible |
visible.vl_code_int |
Restrict delete |
printmap_label_2_visible |
printmap.label_2_visible |
visible.vl_code_int |
Restrict delete |
protectionzone_fk_type |
protectionzone.fk_type |
protectionzone_type.id |
Restrict delete |
pump_fk_pipe_in |
pump.fk_pipe_in |
pipe.id |
Restrict delete |
pump_fk_pipe_out |
pump.fk_pipe_out |
pipe.id |
Restrict delete |
pump_fk_pump_operating |
pump.fk_pump_operating |
pump_operating.id |
Restrict delete |
pump_fk_type |
pump.fk_pump_type |
pump_type.id |
Restrict delete |
pump_id_fkey |
pump.id |
installation.id |
Restrict delete |
remote_fk_distributor |
remote.fk_distributor |
distributor.id |
Restrict delete |
remote_fk_material |
remote.fk_material |
pipe_material.id |
Restrict delete |
remote_fk_precision |
remote.fk_precision |
precision.id |
Restrict delete |
remote_fk_status |
remote.fk_status |
status.id |
Restrict delete |
remote_label_1_visible |
remote.label_1_visible |
visible.vl_code_int |
Restrict delete |
remote_label_2_visible |
remote.label_2_visible |
visible.vl_code_int |
Restrict delete |
samplingpoint_id_fkey |
samplingpoint.id |
network_element.id |
Restrict delete |
source_fk_source_quality |
source.fk_source_quality |
source_quality.id |
Restrict delete |
source_fk_type |
source.fk_source_type |
source_type.id |
Restrict delete |
source_id_fkey |
source.id |
installation.id |
Restrict delete |
subscriber_fk_pipe |
subscriber.fk_pipe |
pipe.id |
Restrict delete |
subscriber_fk_type |
subscriber.fk_subscriber_type |
subscriber_type.id |
Restrict delete |
subscriber_id_fkey |
subscriber.id |
network_element.id |
Restrict delete |
subscriber_reference_fk_subscriber |
subscriber_reference.fk_subscriber |
subscriber.id |
Restrict delete |
surveypoint_fk_folder |
surveypoint.fk_folder |
folder.id |
Restrict delete |
surveypoint_fk_type |
surveypoint.fk_survey_type |
survey_type.id |
Restrict delete |
surveypoint_fk_worker |
surveypoint.fk_worker |
worker.id |
Restrict delete |
surveypoint_id_fkey |
surveypoint.id |
surveypoint.id |
Restrict delete |
tank_cistern1type |
tank.cistern1_fk_type |
cistern.id |
Restrict delete |
tank_cistern2type |
tank.cistern2_fk_type |
cistern.id |
Restrict delete |
tank_fk_overflow |
tank.fk_overflow |
overflow.id |
Restrict delete |
tank_fk_tank_firestorage |
tank.fk_tank_firestorage |
tank_firestorage.id |
Restrict delete |
tank_id_fkey |
tank.id |
installation.id |
Restrict delete |
treatment_id_fkey |
treatment.id |
installation.id |
Restrict delete |
valve_fk_distributor |
valve.fk_distributor |
distributor.id |
Restrict delete |
valve_fk_district |
valve.fk_district |
district.id |
Restrict delete |
valve_fk_folder |
valve.fk_folder |
folder.id |
Restrict delete |
valve_fk_function |
valve.fk_valve_function |
valve_function.id |
Restrict delete |
valve_fk_handle_precision |
valve.fk_handle_precision |
precision.id |
Restrict delete |
valve_fk_handle_precisionalti |
valve.fk_handle_precisionalti |
precisionalti.id |
Restrict delete |
valve_fk_object_reference |
valve.fk_object_reference |
object_reference.id |
Restrict delete |
valve_fk_pipe |
valve.fk_pipe |
pipe.id |
Restrict delete |
valve_fk_precision |
valve.fk_precision |
precision.id |
Restrict delete |
valve_fk_precisionalti |
valve.fk_precisionalti |
precisionalti.id |
Restrict delete |
valve_fk_pressurezone |
valve.fk_pressurezone |
pressurezone.id |
Restrict delete |
valve_fk_status |
valve.fk_status |
status.id |
Restrict delete |
valve_fk_type |
valve.fk_valve_type |
valve_type.id |
Restrict delete |
valve_fk_valve_actuation |
valve.fk_valve_actuation |
valve_actuation.id |
Restrict delete |
valve_label_1_visible |
valve.label_1_visible |
visible.vl_code_int |
Restrict delete |
valve_label_2_visible |
valve.label_2_visible |
visible.vl_code_int |
Restrict delete |
valve_schema_force_visible |
valve.schema_force_visible |
visible.vl_code |
Restrict delete |